How to install an air conditioner - Split Air Conditioner Installation procedure


Selection of installation positions for indoor unit
# To be installed at the position where the air delivered from the unit can reach every corner of the room;
# To avoid being affected by the outdoor air;
# To avoid blockage to the air inlet or outlet of the unit;
# To avoid too much oil smoke or steam;
# To avoid possible generation, inflow, lingering or leakage of flammable gases;
# To avoid high-frequency facilities (such as high frequency arc welders, etc.);
# To avoid the places where acid solutions are frequently used;
# To avoid the places where some special sprayers (sulfides) are frequently used.
# Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm device might be erroneously triggered by the warm air from the unit);
Make sure of enough space for installation and maintenance.
To take into consideration the operational convenience and safety in installation, it is recommended to ensure enough space between the unit and the walls.
Height limits of indoor and outdoor units.
Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated requirements.
Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the performances of the units.
Selection of installation positions for outdoor unit
# To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises;
# To install the unit at the places not to be exposed to rain or direct sunshine, and the places with good ventilation;
# The noises generated from the unit will not affect the neighboring places;
# Do not install the unit on non-metal frame;
# Not to install the unit at the places where there might occur the generation, inflow, stay or leakage of inflammable gases;
# Pay attention to the drainage of the condensed water from the base plate during operations;
# To avoid the air outlet being directly against the wind
Detailed space requirements around the outdoor unit
Installation fixture of indoor unit
Pipelines can be connected in the directions of********and* as indicated in picture. When the pipelines are connected to the directions of***and*, a groove for the pipes has to be opened at the proper place on the base stand.
1. Installation of wall-mounting plate
Fix the wall-mounting plate firmly on the wall with screws. Make sure of the leveling of the plate. Slanted wall-mounting plate might jeopardize the smooth discharge of the condensed water.
2. Drill holes on the wall
Drill holes at places slightly below the wall-mounting plate, with hole diameter of 65mm(2-3/5") and the outer edge of the hole 5-10mm(1/5-2/5") lower  so that the condensed water can smoothly flow out. Cut the wall penetrating pipe to proper length according to the thickness of the wall (3- 5mm(1/10-1/5") longer than the wall thickness) and insert the pipe as indicated in picture
3.Installation of drain pipe
Install the pipelines of the indoor unit in accordance with the direction of the wall holes. Wrap tightly the drain pipe and the pipelines with tape. Make sure that the drain pipe is underneath the pipelines. (When the drain pipe passes the room interior, some condensed water might occur to its surfaces if the humidity is very high).
4.Installation of indoor unit
Pass the connection wires, connecting pipelines and drain pipe through the wall hole. Hang the indoor unit on the hooks at the top of the wall-mounting plate so that the hooks at the bottom of the indoor unit match the hooks of the wall-mounting plate.
Inspections:
a. Check if the hooks at the top and bottom are firmly fixed.
b. Check if the position of the master unit is properly leveled.
c. The drain pipe should not curve upward.
d. The drain pipe should be at the lower part of the wall pipes .
Installation fixture of outdoor unit
# Try to ship the product to the installation location in its original package;
# As the gravity center of the unit is not at the installation center, special caution should be taken when using hoisting cables to lift it up;
# During shipping, the outdoor unit must not be slanted to over 45 degrees (Do not store the unit in a horizontal way).
# Use expansion bolts to fix the mounting supports on the wall;
# Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level;
# If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to resist earthquake or strong wind.
Dimensions for parallel units installations
Pipelines connection
Ordinary pipelines connection (it is suitable for non-quick coupler)
No dust ,foreign articles,air or moisture should be allowed to enter the air conditioning system.Careful attention should be paid when pipeline connection for outdoor unit is made.Try to avoid repeated curves as much as possible,otherwise hardening or cracks might be caused to the copper pipes.Suitable wrenches should be used when the pipeline connection is done so as to ensure appropriate torque.Excessive torque might damage the joints while too little torque might lead to leakage.
Special pipelines connection(it is suitable for quick coupler)
In case of the users purchasing the machine for quick coupler,there is no need to do the air purging procedures and the following pipeline connection procedures should be adopted:
1.Remove the dust caps from the indoor and outdoor units, and the connecting pipe.
2.Align the joint counter of connecting pipe with the proper indoor and outdoor joint conic surfaces,tighten the connecting nut manually.Then,make it secure with a wrench as shown in picture.

3.Remove the two valve core caps from the outdoor unit.
4.Turn on the high and low pressure valve cores with an socket wrench,then tighten the two valve core caps of the outdoor unit .
Notes on installation of quick coupler
1.Connecting pipe bending minimum radius parameters.
2.Quick coupler assembly and disassembly limit: the assembly and disassembly times are inadvisably more than 7.
Air purging
Air purging with vacuum pump
1.Check that pipelines connection have been properly connected,remove the charging port cap,and connect the manifold gauge and the vacuum pump to the charging valve trough a hoses as shown in picture .
2.Open the valve of the low pressure side of manifold gauge,then,run the vacuum pump.Vacuum the indoor unit and the connecting pipes until the pressure in them lowers to below 1.5mmHG (The operation time for vacuuming is about 10 minutes).When the desired vacuum is reached,close the valve of the low pressure of the manifold and stop the vacuum pump.
3.Disconnect the hoses and fit the cap to the charging valve.
4.Remove the blank caps,and fully open the spindles of the 2-way and 3-ways valves with a service valve wrench.
5.Tighten the blank caps of the 2-way and 3-ways valves.
Adding refrigerant
Refrigerant must be added if the piping measures more than 5 metres(16'5") in length.
Additional refrigerant amount
Liquid pipe diameter 6.35(1/4")
Liquid pipe diameter: 9.52(3/8")
(piping length-5)m x 30g
or (piping length-16)ft x 0.3oz
(piping length-5)m x 65g
or (piping length-16)ft x 0.7oz
Gas leakage inspection
After the pipeline connection is done,use a leakage inspection device or soap suds to carefully check if there is any leakage at the joints.This is an important step to ensure the quality of installation.Once a leakage is detected,proper treatment should be taken immediately.
Connection of power cable
1.Remove the drawer of the outdoor unit.
Non-quick coupler: Connect the indoor power and control wires with the matched
Quick coupler: Directly connect quick cable couplers with indoor and outdoor quick cable couplers after disassembly of the outdoor unit connecting box cover
3.Use a press plate to fix the wires firmly,and re-install the drawer.
Finishing touches
# Use thermal tube to wrap the joints and wrap the tube tightly with ethylene tapes.
# Fix the wrapped pipelines on the exterior wall with clamps.
# Fill in the gaps left over by the pipeline hole and wall hole to prevent rain-water from entering.
Test running
# Connect to the power source,check if the function selection keys on the remote controller are working properly.
# Check if the room temperature adjustments and timer settings are working properly.
# Check if the drain is smooth.
# Check if there is any abnormal noise or vibration during operation.
# Check if there is leakage of refrigerant.